21. Full restraint is provided by
(i) Foundation footing of a wall
(ii) Timber floor spanning on the wall and anchored to the wall
(iii) RCC slab with a minimum bearing of 10 cm on the wall
Of these statements
Correct answer: (D)
(i), (ii) and (iii) are correct
22. If is the height of wall between centers of supports, then the effective height of wall where concrete floors have a bearing on wall irrespective of the direction of span will be
Correct answer: (A)
0.75 H
23. If the eccentricity ratio is more than 1/24, then increase in the permissible stress in the design of wall subjected to eccentric loading as per code is
Correct answer: (B)
25 %
24. If the horizontal cross-sectional area of a wall is 1200 cm2, then the basic stress shall be multiplied by a reduction factor equal to
Correct answer: (C)
0.85
25. If the ratio of center to center spacing of intersecting walls to actual thickness of intersecting wall is more than 20, then the stiffening coefficient for wall proper will be
Correct answer: (D)
Greater than 1
26. In a cavity wall, both leaves of which are load bearing, the effective thickness is taken as
Correct answer: (D)
Larger of (B) and (C)
27. In the case of panel wall subjected to horizontal loads at right angles to the plane of the wall, with the mortar not leaner than Ml type, tensile stress in bending in the vertical direction may be allowed to the extent of
Correct answer: (C)
1.0 kg/cm2
28. Maximum slenderness ratio of load bearing walls for a dwelling having more than 2 storeys
(i) Shall not exceed 12 if lime mortar is used
(ii) Shall not exceed 18 if cement lime mortar 1 : 2 : 9 is used
(iii) Shall not exceed 24 if cement mortar 1 : 6 is used Of these statements
Correct answer: (A)
(i) and (ii) are correct
29. Minimum compressive strength in N/mm2 for H1 type mortar used for masonry is
Correct answer: (D)
10
30. Minimum thickness of stiffening wall for 1 to 3 storeys shall not be less than
Correct answer: (A)
10 cm